Product Details

VFD4A8MS21ANSAA Compact Inverter
VFD4A8MS21ANSAA
Name: VFD4A8MS21ANSAA Compact Inverter
Input power (V): 230V 1-Phase
Output current(A): 4.80 A
Motor power (KW): 0.75KW
Protection level: IP20/UL Open Type
Motor Types: IM/IPM/SPM
Description: Delta inverters have now established a broad brand awareness in the industrial automation market. Each series of products is designed for different operating requirements such as torque, loss, overload, and over-speed operation, and is adjusted according to different industrial machinery attributes. It can provide customers with diversified choices and is widely used in industrial automation control.
Built-in brake unit, no built-in filter, built-in PLC
 
1. Support induction motor and permanent magnet motor open circuit control
2. Output frequency range 0 ~ 599Hz (standard model)
3. Built-in PLC programmable (2K steps)
4. Built-in 33kHz high-speed pulse input terminal x1 (MI7)
5. Built-in 33kHz high-speed pulse output terminal x1 (DFM)
6. With safety certification Torque Off (SIL2/PLd)
7. Full range of built-in brake crystals
8. New circuit board coating (IEC 60721-3-3 class 3C2) to strengthen environmental tolerance
9, 5-digit high-brightness led keypad (can be pulled out to the control panel using the E/M/B extension cable)
10. Supports multiple communication interfaces: Profibus DP, Modbus TCP, EtherNet/IP, DeviceNet, CANopen
 
Input power (V) 230V 1-Phase
Output current(A) 4.80
Control method IMVF; IMVFPG; IMSVC (Space Vector Control); IMFOC (Field Oriented Control) Sensorless; PMSVC
Built-in EMC filter No
Built-in DC reactance No
Built-in brake crystal Yes
Motor power (KW) 0.75
Protection level IP20/UL Open Type
Version Wall Mount
Safety Torque Off (STO) Yes
Motor Types Induction Motor (IM); Interior Permanent Magnet Motor (IPM); Surface Permanent Magnet Motor (SPM)
Number input (points) 7
Digital output (points) 2
Relay output (points) 1
Analog input 0 ~ 10V (points) 1
Analog input -10 ~ 10V (points) 1
Analog input 0 ~ 20mA (points) 1
Analog input 4 ~ 20mA (points) 1
Analog output 0 ~ 10V (points) 1
Analog output -10 ~ 10V (points) 0
Analog output 0 ~ 20mA (points) 1
Analog output 4 ~ 20mA (points) 1
Pollution Degree 2
Humidity 90.00
Туре of load Constant Torque; Fan & Pump Application
Types of Workstations Normal Duty; Heavy Duty
Built-in PLC Yes
Support external power supply card Yes
Slot 1 Card Yes
Slot 2 No
Slot 3 Card Not Available
Min Carrier Frequency (kHz) 2
Maximum carrier frequency (kHz) 15
Maximum output frequency (Hz) 599
Drive type Single Drive
Inverter Module Type Single Axis
Rectifier Module Type 不适用
Unit type Inverter Module
Inverter module input voltage 不适用
Built-in motor 不适用

 

Cooling Method Natural
Dimensions (W x H x D) (mm) 72 x 142 x 143
Mounting Wall Mount

 

USB True
RS232 False
RS422 False
RS485/Modbus Serial True
Ethernet/Modbus TCP False
EtherNet/IP False
DeviceNet False
CANopen inv. send ! False
Profibus False
DMCNET False
EtherCAT® False
BACnet MS/TP False
BACnet IP * False
Profinet False
LISO

Privacy Preference Settings

Before continuing to use our website, we need your consent.

If you are under 16 and wish to consent to optional services, you must obtain permission from your legal guardian.

We use cookies and other technologies on our website. Some are necessary, while others help us improve the website and your experience. Personal data may be processed (e.g., IP addresses) for personalized advertising and content or measurement of advertising and content. You can find more information about data usage in ourPrivacy Policy. You can revoke or adjust your choices at any time in theSettings.